FAQ's

As a globally operating company, innovative processes and products are just as much the focus of the Heatcon vision as the awareness of customer requirements worldwide. This makes us a preferred cooperation partner for employees, suppliers, and customers.

Heatcon focuses on the areas of customers, society, and the environment as well as employees in order to realize this vision.

Contact system This system is used when the body (whose temperature is to be measured) and the detector (which is measuring the temperature) can remain in contact with each other, in other words, we can say that if the body and the detector can remain in contact with each other during the dimension of temperature than contact system is used. Non-contact system This system is used when the body (whose temperature is to be measured) and the detector (which is measuring the temperature) aren’t allowed to remain in contact with each other, in other words, we can say that if the body and the detector aren’t allowed to remain in contact with each other during the dimension of temperature also the the-contact system is used.

The thermocouple is a brace of different essence cables joined at one end, which generates a net thermoelectric voltage between open dyads according to the temperature difference between the ends. Working A thermocouple works on the Seebeck Effect, which forms the base of ultramodern thermocouple technology. When two different or unlike essence are joined together at two junctions, an electromotive force (emf) is generated at the two junctions. The quantum of emf generated is different for different combinations of the essence. The junction that’s put into the process in which temperature is being measured is called the HOT JUNCTION. The other junction which is at the last point of thermocouple material and which is nearly always at some kind of measuring instrument is called the COLD JUNCTION.

To elect an ideal thermocouple, first, we need to understand the need for dimension operation. Factors affecting temperature change Delicacy needed-the impact of detector delicacy on overall dimension delicacy. Length of deployment Thermocouple material selection Selection of the Measuring Junction Durability Range of temperature which is to be measured. Determine the outside and minimal range in which you want to measure the temperature and elect the thermocouple with an advanced Maximum temperature range. Check whether the linearity of the thermocouple meets the range demand. Environmental Consideration Elect the correct jacket material to repel chemical responses. Perfect Insulation to repel noise protection. The thermocouple should repel vibration and bruise. Applicable connectors and lines to be used between thermocouples and measuring instruments. Applicable measuring instruments should be used to give an accurate result.

The use of thermistors is generally limited to many hundred degrees Celsius and manufacturers advise that extended exposures will beget the thermistor to drift out of its specified forbearance. Thermistors can be made veritably small which means they will respond snappily to temperature changes. It also means that their small thermal mass makes them especially susceptible to tone-heating crimes. Thermistors are a good deal more fragile than RTD’s or thermocouples and they must be precisely mounted to avoid crushing or bond separation.

Forbearance on Temperature Reading Forbearance denotes the maximum permissible value attained by abating the temperature reading or the temperature at the hot junction from the standard temperature converted from the applicable temperature EMF table. Maximum Operating Temperature The operating temperature limit means the upper temperature where thermocouples can be used continuously. Maximum limit means the upper temperature where thermocouples can be used temporarily for a short period of time owing to necessary circumstances.

Small overall dimension and high inflexibility, which enables temperature dimension in locales with poor availability. Good mechanical strength.