Data Loggers

            Data Loggers

8003-USB / 90 x 180 MM - Data Acquisition System

Features

  • USB is used for data logging
  • Menu Driven Programming via Front Panel Keys
  • Real Time Temperature Scanning
  • 16×2 LCD Used for normal monitoring 
  • Alarm relay for Alarming Applications
  • Available sizes are 90×90 and 90×180
  • Custom made properties

Applications

  • ISO certification records, Validating process certifying
  • Pharmaceutical process validation with graph & excel report in Autoclaves
  • Online profile recording for Oven & BOD, Incubator, Humidity Chamber
  • Winding temperature of generators, Bearings, motors, transformers
  • To know heat profile in furnace, foundries for heat treatment application
  • Primary & Auxiliary temperature scanning for boiler
  • Chemical & Hazardous area where data monitoring is essential
  • Room Mapping in Pharmaceutical  

Specification

  • Parameters: Temperature ( -200℃ to +1800℃)
  • Humidity (5-95%)
  • Pressure (1-750 bar)
  • Voltage/Current/Mass etc
  • Size: 90×90, 190×125, 180×90
  • Of channels: 1/ 4 / 8 / 12 / 16 **
  • Measuring Time: 3 – 40 readings /sec*
  • Ambient Temperature: Should not exceed 70℃ (Customized)
  • Construction: Panel mountable / Table Top 
  • Display: 3½ digit LED displays / LCD (16 x 2)
  • Computer Interfaces: RS-232 / USB(with Graphical Software for Windows)
  • Interfaces: CAN (Model : 8003 -CAN), Wireless(8003-RF), GSM (Model: 8003 -GSM)
  • RS 485 (Model : 9003 -BUS)
  • Resolution: 1/1 v
  • Accuracy: ±0.1%
  • Alarm: Configurable 2 number single pole 1 NO/1
  • NC Relay of Rating 5 Amps at 230V
  • Memory: Flash Drive
  • Printer: Built in printer is available
  • Input Power: 230V / 50 Hz Power Supply

*- Measuring Time till varies for different models

 ** – Upto 128 channels can be accommodated.

8003-USB / 90 x 90 MM - USB Data Logger

Features

  • USB is used for data logging
  • Menu Driven Programming via Front Panel Keys
  • Real Time Temperature Scanning
  • 16×2 LCD Used for normal monitoring 
  • Alarm relay for Alarming Applications
  • Available sizes are 90×90 and 90×180
  • Custom made properties

Applications

  • ISO certification records, Validating process certifying
  • Pharmaceutical process validation with graph & excel report in Autoclaves
  • Online profile recording for Oven & BOD, Incubator, Humidity Chamber
  • Winding temperature of generators, Bearings, motors, transformers
  • To know heat profile in furnace, foundries for heat treatment application
  • Primary & auxiliary temperature scanning for boiler
  • Chemical & Hazardous area where data monitoring is essential
  • Room Mapping in Pharmaceutical 
Description

Specification of USB Data Logger 

  • Parameters: Temperature ( -200℃ to +1800℃)
  • : Humidity (5-95%)
  • Pressure (1-750 bar)
  • Voltage/Current/Mass etc
  • Size: 90 x 90, 190 x  125, 180 x 90
  • Of channels: 1/ 4 / 8 / 12 / 16 **
  • Measuring Time: 3 – 40 readings /sec*
  • Ambient Temperature: Should not exceed 70℃ (Customized)
  • Construction : Panel mountable / Table Top 
  • Display: 3½ digit LED displays / LCD (16 x 2)
  • Memory: Flash Drive
  • Printer: Built in printer is available
  • Input Power: 230V / 50 Hz Power Supply

 *- Measuring Time till varies for different models

 ** – Upto 128 channels can be accommodated. 

9002 / 90 x 180 MM - Data Logger

Features

  • RS232 communication to interface with computer
  • Menu driven Programming via Front Panel Keys
  • Real Time Temperature Scanning
  • Using seven segment displays for normal monitoring 
  • Alarm Relay for Alarming Applications
  • Available sizes are 90×180
  • Custom made Seven segment Display size

Applications

  • ISO certification records, Validating process certifying
  • Pharmaceutical process validation with graph & excel report in Autoclaves
  • Online profile recording for Oven & BOD, Incubator, Humidity Chamber
  • Winding temperature of generators, Bearings, motors, transformers
  • To know heat profile in furnace, foundries for heat treatment application
  • Primary & auxiliary temperature scanning for boiler
  • Chemical & Hazardous area where data monitoring is essential
  • Room Mapping in Pharmaceutical 

Specification of Data Logger 

  • Parameters: Temperature ( -200℃ to +1800℃)
  • : Humidity (5-95%)
  • Pressure (1-750 bar)
  • Voltage/Current/Mass etc
  • Size: 90 x 90, 190 x  125, 180 x 90
  • Of channels: 1/ 4 / 8 / 12 / 16 **
  • Measuring Time: 3 – 40 readings /sec*
  • Ambient Temperature : Should not exceed 70℃ (Customized)
  • Construction: Panel mountable / Table Top 
  • Display: 3½ digit LED displays / LCD (16 x 2)
  • Computer Interfaces : RS-232 / USB(with Graphical Software for Windows)
  • Interfaces: CAN (Model : 8003 -CAN), Wireless(8003-RF), GSM (Model: 8003 -GSM)
  • RS 485 (Model : 9003 -BUS)
  • Resolution : 1/1 v
  • Accuracy: ±0.1%
  • Alarm: Configurable 2 number single pole 1 NO/1
  • NC Relay of Rating 5 Amps at 230V
  • Memory: Flash Drive
  • Printer: Built in printer is available
  • Input Power: 230V / 50 Hz Power Supply

*- Measuring Time till varies for different models

** – Upto 128 channels can be accommodated.

9002 / 90 x 90 MM - Data Logger

Features

  • RS232 communication to interface with computer
  • Menu driven Programming via Front Panel Keys
  • Real Time Temperature Scanning
  • Using seven segment displays for normal monitoring 
  • Alarm Relay for Alarming Applications
  • Available sizes are 90×90
  • Custom made Seven segment Display size

Applications

  • ISO certification records, Validating process certifying
  • Pharmaceutical process validation with graph & excel report in Autoclaves
  • Online profile recording for Oven & BOD, Incubator, Humidity Chamber
  • Winding temperature of generators, Bearings, motors, transformers
  • To know heat profile in furnace, foundries for heat treatment application
  • Primary & auxiliary temperature scanning for boiler
  • Chemical & Hazardous area where data monitoring is essential
  • Room Mapping in Pharmaceutical 

Specification of Data Logger 

  • Parameters: Temperature ( -200℃ to +1800℃)
  • : Humidity (5-95%)
  • Pressure (1-750 bar)
  • Voltage/Current/Mass etc
  • Size: 90 x 90, 190 x  125, 180 x 90
  • Of channels : 1/ 4 / 8 / 12 / 16 **
  • Measuring Time: 3 – 40 readings /sec*
  • Ambient Temperature: Should not exceed 70℃ (Customized)
  • Construction: Panel mountable / Table Top 
  • Display: 3½ digit LED displays / LCD (16 x 2)
  • Computer Interfaces: RS-232 / USB(with Graphical Software for Windows)
  • Interfaces: CAN (Model : 8003 -CAN), Wireless(8003-RF), GSM (Model: 8003 -GSM)
  • RS 485 (Model: 9003 -BUS)
  • Resolution: 1/1 v
  • Accuracy: ±0.1%
  • Alarm: Configurable 2 number single pole 1 NO/1
  • NC Relay of Rating 5 Amps at 230V
  • Memory: Flash Drive
  • Printer: Built in printer is available
  • Input Power: 230V / 50 Hz Power Supply

 *- Measuring Time till varies for different models